<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Automation News &#187; Networks</title>
	<atom:link href="http://www.automationnews.org/category/technical/networks/feed" rel="self" type="application/rss+xml" />
	<link>http://www.automationnews.org</link>
	<description></description>
	<lastBuildDate>Thu, 09 Sep 2010 09:57:26 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Cellular for Industrial Control</title>
		<link>http://www.automationnews.org/cellular-for-industrial-control/1080</link>
		<comments>http://www.automationnews.org/cellular-for-industrial-control/1080#comments</comments>
		<pubDate>Mon, 16 Aug 2010 11:00:28 +0000</pubDate>
		<dc:creator>Doug Brock</dc:creator>
				<category><![CDATA[Networks]]></category>

		<guid isPermaLink="false">http://www.automationnews.org/?p=1080</guid>
		<description><![CDATA[Cellular modems have been around for a few years now. It&#8217;s great for pumping stations and other remote small systems. It&#8217;s also a great way to update radio notification systems. Plug the cellular modem into your controller and you have an easy way to text alarm messages to maintenance guys or to text production data [...]


Related posts:<ol><li><a href='http://www.automationnews.org/stuxnet-and-industrial-control-system-security/1033' rel='bookmark' title='Permanent Link: Stuxnet and Industrial Control System Security'>Stuxnet and Industrial Control System Security</a></li>
<li><a href='http://www.automationnews.org/siemens-industrial-automation-systems-under-malware-threat/932' rel='bookmark' title='Permanent Link: Siemens Industrial Automation Systems Under Malware Threat'>Siemens Industrial Automation Systems Under Malware Threat</a></li>
<li><a href='http://www.automationnews.org/emerson-acquires-innovative-control-systems/739' rel='bookmark' title='Permanent Link: Emerson Acquires Innovative Control Systems'>Emerson Acquires Innovative Control Systems</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/cellular-for-industrial-control/1080/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Stuxnet and Industrial Control System Security</title>
		<link>http://www.automationnews.org/stuxnet-and-industrial-control-system-security/1033</link>
		<comments>http://www.automationnews.org/stuxnet-and-industrial-control-system-security/1033#comments</comments>
		<pubDate>Tue, 03 Aug 2010 02:43:49 +0000</pubDate>
		<dc:creator>Doug Brock</dc:creator>
				<category><![CDATA[Networks]]></category>
		<category><![CDATA[Tutorials]]></category>

		<guid isPermaLink="false">http://www.automationnews.org/?p=1033</guid>
		<description><![CDATA[The Stuxnet virus has generated a lot of renewed interest in network security for industrial control systems. The following are some of the general tips that come from major controls manufacturers: Disable the Autoplay feature for CD players and for removable drives and implement a strict policy for the use of USB drives on all enterprise and [...]


Related posts:<ol><li><a href='http://www.automationnews.org/siemens-industrial-automation-systems-under-malware-threat/932' rel='bookmark' title='Permanent Link: Siemens Industrial Automation Systems Under Malware Threat'>Siemens Industrial Automation Systems Under Malware Threat</a></li>
<li><a href='http://www.automationnews.org/cellular-for-industrial-control/1080' rel='bookmark' title='Permanent Link: Cellular for Industrial Control'>Cellular for Industrial Control</a></li>
<li><a href='http://www.automationnews.org/chuck-grindstaff-new-president-of-siemens-plm-software/1131' rel='bookmark' title='Permanent Link: Chuck Grindstaff New President of Siemens PLM Software'>Chuck Grindstaff New President of Siemens PLM Software</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/stuxnet-and-industrial-control-system-security/1033/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DeviceNet Network Installation Checklist</title>
		<link>http://www.automationnews.org/devicenet-network-installation-checklist/361</link>
		<comments>http://www.automationnews.org/devicenet-network-installation-checklist/361#comments</comments>
		<pubDate>Fri, 19 Mar 2010 11:24:54 +0000</pubDate>
		<dc:creator>Nima Heydarian</dc:creator>
				<category><![CDATA[Networks]]></category>
		<category><![CDATA[DeviceNet]]></category>

		<guid isPermaLink="false">http://www.automationfieldengineer.com/?p=361</guid>
		<description><![CDATA[If you are setting up your DeviceNet network or it is not working properly go through the following checklist. It will fix your problem 95% of the time. Termination resistors. ( 1 at each end of trunk ). Grounding of Network. ( One location only ). Cumulative drop line budget in spec. for selected baud [...]


Related posts:<ol><li><a href='http://www.automationnews.org/devicenet-diagnostic-faceplate-rsview/421' rel='bookmark' title='Permanent Link: DeviceNet Diagnostic Faceplate For RSView ME (SE)'>DeviceNet Diagnostic Faceplate For RSView ME (SE)</a></li>
<li><a href='http://www.automationnews.org/devicenet-cables/300' rel='bookmark' title='Permanent Link: DeviceNet Thick Cable Communication Media'>DeviceNet Thick Cable Communication Media</a></li>
<li><a href='http://www.automationnews.org/siemens-joins-algaework-alliance-network/1133' rel='bookmark' title='Permanent Link: Siemens joins Algae@Work Alliance Network'>Siemens joins Algae@Work Alliance Network</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/devicenet-network-installation-checklist/361/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DeviceNet Thick Cable Communication Media</title>
		<link>http://www.automationnews.org/devicenet-cables/300</link>
		<comments>http://www.automationnews.org/devicenet-cables/300#comments</comments>
		<pubDate>Mon, 08 Mar 2010 03:33:58 +0000</pubDate>
		<dc:creator>Nima Heydarian</dc:creator>
				<category><![CDATA[Networks]]></category>
		<category><![CDATA[DeviceNet]]></category>

		<guid isPermaLink="false">http://www.automationfieldengineer.com/?p=300</guid>
		<description><![CDATA[DeviceNet network can use Thick Cable, Thin Cable, and Flat Cable types for communication. Some of the features and qualities of the thick cable type used in DeviceNet networks are: The Signal pair (#18) is the blue/white wire Power pair (#15) is the black/red wire PVC/nylon insulation on power pair Industrial temperature range Storage: -40o [...]


Related posts:<ol><li><a href='http://www.automationnews.org/devicenet-network-installation-checklist/361' rel='bookmark' title='Permanent Link: DeviceNet Network Installation Checklist'>DeviceNet Network Installation Checklist</a></li>
<li><a href='http://www.automationnews.org/devicenet-diagnostic-faceplate-rsview/421' rel='bookmark' title='Permanent Link: DeviceNet Diagnostic Faceplate For RSView ME (SE)'>DeviceNet Diagnostic Faceplate For RSView ME (SE)</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/devicenet-cables/300/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Repeaters in ControlNet Network Topologies</title>
		<link>http://www.automationnews.org/repeaters-in-controlnet-network-topologies/261</link>
		<comments>http://www.automationnews.org/repeaters-in-controlnet-network-topologies/261#comments</comments>
		<pubDate>Thu, 25 Feb 2010 21:30:19 +0000</pubDate>
		<dc:creator>Nima Heydarian</dc:creator>
				<category><![CDATA[Networks]]></category>
		<category><![CDATA[ControlNet]]></category>

		<guid isPermaLink="false">http://www.automationfieldengineer.com/?p=261</guid>
		<description><![CDATA[Repeaters can be used in various topologies in ControlNet networks. Following are the four topologies with their features: Bus Topology Repeaters have to be in series. This is the most basic (and more common) layout Star Topology Repeaters are configured as hubs in this configuration Tree Topology Repeaters have to be in parallel form This [...]


Related posts:<ol><li><a href='http://www.automationnews.org/devicenet-network-installation-checklist/361' rel='bookmark' title='Permanent Link: DeviceNet Network Installation Checklist'>DeviceNet Network Installation Checklist</a></li>
<li><a href='http://www.automationnews.org/controlnet-diagnostic-faceplate-for-rsview-me-se/422' rel='bookmark' title='Permanent Link: ControlNet Diagnostic Faceplate For RSView ME (SE)'>ControlNet Diagnostic Faceplate For RSView ME (SE)</a></li>
<li><a href='http://www.automationnews.org/controllogix-message-instruction-path/235' rel='bookmark' title='Permanent Link: ControlLogix Message Instruction Path'>ControlLogix Message Instruction Path</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/repeaters-in-controlnet-network-topologies/261/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>What does OUI Stand for?</title>
		<link>http://www.automationnews.org/what-does-oui-stand-for/243</link>
		<comments>http://www.automationnews.org/what-does-oui-stand-for/243#comments</comments>
		<pubDate>Thu, 11 Feb 2010 13:54:43 +0000</pubDate>
		<dc:creator>Nima Heydarian</dc:creator>
				<category><![CDATA[Networks]]></category>

		<guid isPermaLink="false">http://www.automationfieldengineer.com/?p=243</guid>
		<description><![CDATA[OUI stands for Organizational Unique Identifier Related posts:What do CAN, WAN, GAN, LAN, MAN Stand For?


Related posts:<ol><li><a href='http://www.automationnews.org/what-do-can-wan-gan-lan-man-stand-for/239' rel='bookmark' title='Permanent Link: What do CAN, WAN, GAN, LAN, MAN Stand For?'>What do CAN, WAN, GAN, LAN, MAN Stand For?</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/what-does-oui-stand-for/243/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>What do CAN, WAN, GAN, LAN, MAN Stand For?</title>
		<link>http://www.automationnews.org/what-do-can-wan-gan-lan-man-stand-for/239</link>
		<comments>http://www.automationnews.org/what-do-can-wan-gan-lan-man-stand-for/239#comments</comments>
		<pubDate>Thu, 11 Feb 2010 13:30:37 +0000</pubDate>
		<dc:creator>Nima Heydarian</dc:creator>
				<category><![CDATA[Networks]]></category>

		<guid isPermaLink="false">http://www.automationfieldengineer.com/?p=239</guid>
		<description><![CDATA[These are all networks related terms. CAN: Campus Area Network WAN: Wide Area Network GAN: Global Area Network LAN: Local Area Network MAN: Metropolitan Area Network Related posts:What does OUI Stand for? Stuxnet and Industrial Control System Security DeviceNet Network Installation Checklist


Related posts:<ol><li><a href='http://www.automationnews.org/what-does-oui-stand-for/243' rel='bookmark' title='Permanent Link: What does OUI Stand for?'>What does OUI Stand for?</a></li>
<li><a href='http://www.automationnews.org/stuxnet-and-industrial-control-system-security/1033' rel='bookmark' title='Permanent Link: Stuxnet and Industrial Control System Security'>Stuxnet and Industrial Control System Security</a></li>
<li><a href='http://www.automationnews.org/devicenet-network-installation-checklist/361' rel='bookmark' title='Permanent Link: DeviceNet Network Installation Checklist'>DeviceNet Network Installation Checklist</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.automationnews.org/what-do-can-wan-gan-lan-man-stand-for/239/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
